Fast Sense hydrogen sensors and H₂ analyzers provide real-time transformer monitoring for utilities and industries. Detect dissolved gases early, prevent costly failures, and extend asset life.

Transformer Monitoring with Hydrogen Sensors & H₂ Analyzers

Hydrogen sensors and H₂ analyzers provide real-time transformer monitoring for utilities and industries. Detect dissolved gases early, prevent costly failures, and extend asset life.

Transformer Monitoring with Hydrogen Sensors & H₂ Analyzers

Transformers are the backbone of both utility grids and industrial facilities. Yet undetected faults can cause dissolved gases like hydrogen (H) and methane (CH) to build up inside transformer oil. This buildup signals early warning signs of arcing, overheating, or insulation breakdown.

Traditional dissolved gas analysis (DGA) is done via periodic sampling — costly, time-consuming, and reactive. Fast Sense provides a continuous, real-time hydrogen sensing solution that transforms monitoring from reactive to predictive.

Why Hydrogen Sensors Are Critical for Transformers

By deploying Fast Sense H analyzers, operators can extend transformer lifespan, reduce unplanned failures, and safeguard infrastructure.

Technical Deep Dive: H₂ Sensing in Transformers

Our probe-type hydrogen sensors measure dissolved gases in transformer oil directly.

Compared to infrared or catalytic sensors, Fast Sense’s chemical-resistive nano-sensor array delivers stability and longevity with minimal recalibration cycles.

Case Studies

Industry Data

Internal Links

ParameterSpecification
Operating Pressure at the Sensor inletRecommended: 5 mbar – 100 mbar absolute (0.7 – 1.5 psia)
Sensor Response Time< 10 s
CalibrationFactory calibrated at 5 mbar and 0.2 slpm (higher pressure sensors available on request)
Process Gas Temperature-5°C to 55°C
Flow Rate0.1 to 0.6 slpm
Operating Humidity< 95% RH (non-condensing)
Calibration Interval1 year
Measurement Range in Blend0.01 – 99.9%
Accuracy< 3% of the reading
Resolution0.01% (low H₂ conc. range) – 0.1% (high H₂ conc. range)
Measurement Period~ 20 min (varies from 1 min to 40 min, based on concentration range)

FAQ's

Can hydrogen sensors detect both dissolved and leaked gases?

Yes. Fast Sense solutions combine dissolved gas analyzers for oil with leak detection sensors for cabinets and vaults.

How do H₂ analyzers compare to traditional DGA?

DGA is periodic and reactive. Fast Sense analyzers provide continuous, real-time data.

What’s the lifetime of these sensors?

Our hydrogen sensors last 5+ years with minimal recalibration.

Are they SCADA-compatible?

Yes, multiple interfaces (USB, Modbus, 4–20 mA, BLE).