Over 10 years we help companies reach their financial and branding goals. Engitech is a values-driven technology agency dedicated.

Gallery

Contacts

411 University St, Seattle, USA

engitech@oceanthemes.net

+1 -800-456-478-23

Fast Sense hydrogen sensors and H₂ analyzers provide real-time transformer monitoring for utilities and industries. Detect dissolved gases early, prevent costly failures, and extend asset life.

CCUS & Hydrogen Integration | H₂ Sensors & Gas Analysis for Carbon Capture

Hydrogen sensors and H₂ analyzers ensure safe and efficient CCUS by monitoring CO₂ purity, detecting hydrogen slip, and protecting pipelines from embrittlement.

The Role of Hydrogen Sensors in CCUS

Carbon Capture, Utilization & Storage (CCUS) is a cornerstone technology for decarbonizing hard-to-abate sectors such as steel, cement, refining, and hydrogen production. By capturing CO₂ emissions and either reusing or storing them underground, CCUS reduces carbon footprints while supporting the hydrogen economy.

However, CCUS systems rely on precise gas analysis. Hydrogen slip during separation, CO₂ purity in capture units, and leaks in pipelines all pose operational and safety challenges. This is where hydrogen sensors and H₂ analyzers play a vital role.

Fast Sense delivers advanced H₂ sensing and multi-gas analyzers that monitor CO₂, H₂, CH₄, and impurities across the capture, transport, and storage chain — ensuring efficiency, compliance, and long-term infrastructure safety.

Why CCUS Requires H₂ Sensing and Gas Analysis

Without continuous monitoring from H₂ analyzers, CCUS operators risk equipment degradation, pipeline failures, and regulatory non-compliance.

Technical Deep Dive: H₂ Analysis in CCUS

Fast Sense hydrogen analyzers and sensors are engineered for:

Key Capabilities:

Case Studies

Industry Stats

Operational Benefits of Fast Sense H₂ Sensors

Future Trends in CCUS & Hydrogen

ParameterSpecification
Operating Pressure at the Sensor inletRecommended: 5 mbar – 100 mbar absolute (0.7 – 1.5 psia)
Sensor Response Time< 10 s
CalibrationFactory calibrated at 5 mbar and 0.2 slpm (higher pressure sensors available on request)
Process Gas Temperature-5°C to 55°C
Flow Rate0.1 to 0.6 slpm
Operating Humidity< 95% RH (non-condensing)
Calibration Interval1 year
Measurement Range in Blend0.01 – 99.9%
Accuracy< 3% of the reading
Resolution0.01% (low H₂ conc. range) – 0.1% (high H₂ conc. range)
Measurement Period~ 20 min (varies from 1 min to 40 min, based on concentration range)

FAQ's

What is hydrogen slip in CCUS?

It refers to unseparated H₂ escaping with CO₂, reducing capture efficiency and potentially damaging downstream equipment.

Can hydrogen analyzers detect ppm levels in CO₂ streams?

Yes, Fast Sense sensors measure hydrogen from ppm to % levels, critical for CO₂ transport pipelines.

Why is hydrogen analysis essential in CO₂ storage?

Trace hydrogen affects reservoir integrity and storage safety — monitoring ensures compliance and safety.

How do Fast Sense analyzers compare to traditional gas chromatography?

They provide real-time, inline monitoring, avoiding delays and costly lab testing.