Fast Sense hydrogen sensors and H₂ analyzers provide real-time transformer monitoring for utilities and industries. Detect dissolved gases early, prevent costly failures, and extend asset life.

Hydrogen Sensors for Battery Safety & BESS Fire Prevention | Fast Sense

Protect energy storage and industrial platforms with hydrogen sensors and H₂ analyzers from Fast Sense. Detect early gas emissions to prevent thermal runaway and fires.

Battery Safety with Hydrogen Sensors & Gas Analyzers

Energy storage is scaling globally — but so are the risks. Battery Energy Storage Systems (BESS) and home batteries face growing safety challenges. Thermal runaway events often release gases like hydrogen, carbon monoxide, and VOCs minutes before smoke or fire is visible.

Traditional smoke and heat detectors react too late. Fast Sense hydrogen sensors and analyzers provide early detection of gas emissions, allowing preventive action before catastrophe strikes.

Why Hydrogen Sensing is Essential for Battery Platforms

Fast Sense sensors provide real-time H₂ analysis at ppm levels, helping operators intervene before events escalate.

Technical Deep Dive: H₂ Detection in Batteries

Our nano-sensor arrays ensure sensitivity without false positives from environmental noise.

Case Studies

Industry Data

Internal Links

ParameterSpecification
Operating Pressure at the Sensor inletRecommended: 5 mbar – 100 mbar absolute (0.7 – 1.5 psia)
Sensor Response Time< 10 s
CalibrationFactory calibrated at 5 mbar and 0.2 slpm (higher pressure sensors available on request)
Process Gas Temperature-5°C to 55°C
Flow Rate0.1 to 0.6 slpm
Operating Humidity< 95% RH (non-condensing)
Calibration Interval1 year
Measurement Range in Blend0.01 – 99.9%
Accuracy< 3% of the reading
Resolution0.01% (low H₂ conc. range) – 0.1% (high H₂ conc. range)
Measurement Period~ 20 min (varies from 1 min to 40 min, based on concentration range)

FAQ's

What gases do Fast Sense sensors detect in BESS?

Hydrogen, CO, VOCs, and methane, depending on configuration.

Can these sensors stop fires?

They provide early warning, allowing preventive shutdowns and ventilation — often stopping fires before ignition.

How accurate are they?

Detection thresholds are ppm-level, much earlier than heat or smoke alarms.

Do they require maintenance?

Minimal recalibration cycles, long life >5 years.