Fast Sense are always looking for creative annd ambitious molecule management tasks and ready for challenges! Hire Us
MGA-3000 Multi Gas Analyzer
- Home
- Instruments
- #Hydrogen
- #Sensor
- #Instrument
- #H2Detection
DATAECO™ MGA-3000 Hydrogen Analyzer
Hydrogen Quantification for Pipelines and Process Control
High-precision multi-gas analyzer for hydrogen, methane, and CO₂ detection in ATEX Zone 1 hazardous areas. Designed for refinery process control and pipeline injection monitoring.

MEASUREMENT INSTRUMENT
DATAECO™ MGA-3000 Multi Gas Analyzer
Designed to operate reliably in harsh and hazardous environments, this multi-gas analyzer provides continuous, real-time insight into critical gas compositions. By accurately quantifying hydrogen alongside methane and CO₂, it enables operators to optimise refinery processes, control blending ratios, and ensure safe and compliant pipeline injection. Unlike traditional systems, it delivers fast response times and scalable deployment, supporting both point measurements and distributed monitoring across complex infrastructure.
Headline Features
- Fast hydrogen detection with high sensitivity
- Low power consumption, suitable for embedded systems
- Wide operating hydrogen concentration range (and humidity range)
- High selectivity against common interfering gases (CH₄, CO₂)
- Compact, robust package for industrial environments
- Compatible with external digital or analog readout electronics
Technical Specifications
Detection & Performance
- Target Gas
- Hydrogen (H₂), Methane (CH₄), Carbon Dioxide (CO₂)
- Detection Range
- Typical: 0–99.9% vol H₂
- Repeatability
- < 0.1%
- Auxiliary Sensors
- Temperature & Humidity sensor
- Sensitivity Resolution
- 0.05% of the reading
- Response Time (T90)
- < 30 sec (projected < 3 s)
Environmental Specifications
- Operating Temperature
- -20 °C to +80 °C
- Storage Temperature
- -20 °C to +85 °C
- Operating Humidity
- Up to 95% RH, non-condensing
- Pressure
- Atmospheric pressure (<100 mbar)
Electrical Characteristics
- Supply Power (Solenoid)
- 12–28 V (recommended 24 V)
- Supply Power (4-20mA)
- 12–28 V (recommended 24 V)
- Supply Power (Equipment)
- 12–15 V (recommended 12 V)
- Supply Power (Modbus)
- 12–28 V (recommended 24 V)
- Power Consumption (Average)
- < 0.6 W
- Power Consumption (Peak)
- < 1.2 W
Applications
Delivering reliable performance even in the most demanding environments.
- Process Control
- Pipeline Injection
- Electrolyzers
- Transformers
Ready to Get Started?
Pre-order your unit or request a technical brief from our engineering team.
3D Model — Coming Soon
Sales enquiries — Fast Sense
Are you interested in our solutions? Then write us a message. Our sales team will be happy to help you.