Fast Sense are always looking for creative annd ambitious molecule management tasks and ready for challenges! Hire Us
FP-200 Point Detector
- #Hydrogen
- #Sensor
- #Instrument
- #H2Detection
H2FAST™ FP-200 Point Detector
Continuous, fast, 24/7 monitoring for hydrogen leaks in industrial settings to detect concentrations ranging from ppm (parts per million) up to 100% of the Lower Explosive Limit (LEL).
Ultra-compact fixed-point hydrogen & VOC detector with ppm-level sensitivity. Ideal for energy storage, transportation, and measuring station applications.

InAir Mountable
H2FAST™ FP-200 Point Detector
With flexible sensing configurations, the H2FAST™ FP-200 can be equipped with VOC or methane detection, extending its capability beyond hydrogen monitoring. Designed to function as part of a distributed sensing network, each unit can operate as a connected node across indoor and outdoor environments. This enables scalable, multi-gas monitoring across complex sites, providing operators with a more complete view of asset conditions, improved situational awareness, and enhanced safety across the entire system.
Headline Features
- Fast hydrogen detection with high sensitivity
- VOC detection with high sensitivity (Optional)
- CH4 detection with high sensitivity (Optional)
- Low power consumption, suitable for embedded systems
- Wide operating hydrogen concentration range (and humidity range)
- High selectivity against common interfering gases (CH₄, CO₂)
- Compact, robust package for industrial environments
- Compatible with external digital or analog readout electronics
Technical Specifications
Detection & Performance
- Target Gas
- Hydrogen (H₂), Volatile Organic Compounds (VOCs)
- Detection Range
- H2 0–50,000 ppm, VOC 0-1000 ppm
- Linearity
- Linear up to 50,000 ppm
- Repeatability
- 50 ppm
- Auxiliary Sensors
- Temperature & Humidity sensor
- Sensitivity Resolution
- ~ 50 ppm or 0.05% of the reading
- Response Time (T90)
- < 60 s (projected < 3 s)
Environmental Specifications
- Operating Temperature
- -20 °C to +80 °C
- Storage Temperature
- -20 °C to +85 °C
- Operating Humidity
- Up to 95% RH, non-condensing
- Pressure
- Atmospheric pressure (<100 mbar)
Electrical Characteristics
- Supply Power (RS-485)
- 12 V
- Supply Power (Equipment)
- 2.7 to 30 V (9V or 12V recommended)
- Power Consumption (Average)
- < 0.05 W
- Power Consumption (Peak)
- < 0.1 W
- Energy Storage
- Transportation
Applications
Delivering reliable performance even in the most demanding environments.
- Energy Storage
- Transportation
- Measuring Stations
Ready to Get Started?
Pre-order your unit or request a technical brief from our engineering team.
3D Model — Coming Soon